Synthetic Underlayment for Residential Roofing in North America

A roofing contractor in North America once covered a house with a residential roofing underlayment in the morning and returned after a weekend to find the laps lifting at one slope. The fastening pattern had been sufficient for felt and not for the wider sheets of the synthetic product.

North American residential roofing has moved from asphalt-saturated felt to synthetic underlayment over the last two decades, and the installation practice has had to move with it. A north america roof underlayment is lighter, wider and slicker than felt, and each of those differences changes how the sheet is handled. This article covers how a synthetic underlayment installation is planned for a North American house, from deck preparation to the last lap.

1. Why North America Roof Underlayment Changed

A north america roof underlayment is now usually a synthetic sheet, and the change followed from the same set of failures that drove it elsewhere, with a North American pattern.

Felt remained common in North America longer than in some other markets because it was inexpensive and familiar, and it was produced locally in the common widths. The change came as the limits of felt became visible: brittleness as the asphalt aged, tearing at fasteners when a crew walked the roof, and a limited exposure period in a wet season.

DriverFeltSynthetic
Flexibility over timeBrittle as it agesRetains flexibility
Tear at fastenersLow resistanceHigh resistance
Weight per squareHeavyLight
Exposure periodShortLonger
Surface frictionHigherLower, needs care

The lighter weight is a practical benefit on a residential roof, because the rolls can be carried up a ladder by one person rather than two. The lighter weight also changes the handling: a light roll moves in the wind, and an unsealed lap on a north america roof underlayment opens more readily than on a heavy felt.

The lower surface friction is the difference that most often shows up as a site problem. A synthetic sheet is slicker underfoot than felt, and a crew that is used to felt has to adjust, particularly on a steep slope or on a morning with dew.

2. Residential Roofing Underlayment Selection

A residential roofing underlayment is selected on the slope, the exposure and the covering, and the figures follow from those three.

The slope decides whether the roof is treated as steep or low slope. A steep roof sheds water quickly and the underlayment is a secondary layer during construction and after a failure. A low-slope roof sheds water slowly and the sheet has to hold a head of water for longer, so the water resistance figure matters more.

Roof ConditionWhat It Sets
Steep slopeLower water resistance requirement
Low slopeHigher water resistance, ponding risk
Long exposureLonger rated exposure period
High windHigher tear and fastening requirement
Valleys and eavesIce and water shield in addition

The covering also matters. Asphalt shingles, metal panels and tiles each place a different demand on the underlayment and each has its own fastening pattern into the deck. The underlayment should be selected to suit the covering rather than in isolation.

The exposure period is often the deciding figure on a residential project, because the covering may not be installed for days or weeks after the deck is wrapped. A sheet rated for a longer exposure gives the schedule more room, and exceeding the stated period risks a failure that is then hidden under the new roof.

3. Synthetic Underlayment Installation on a House

A synthetic underlayment installation follows a sequence, and the sequence matters more than the speed at which it is done.

The deck is prepared first. Any protruding fastener is set flush, any damaged sheathing is replaced and the surface is swept. A protrusion under a synthetic sheet is a point load that can puncture the sheet when it is walked on.

The sheet is then rolled out in horizontal courses working up the slope, with the upper course lapping over the lower one. The laps should be set to the manufacturer's figure, which is usually marked on the sheet.

StageWhat Is Checked
Deck preparationFlush fasteners, sound sheathing
First courseStraight start line, eaves detail
Lap directionUpper course over lower
FasteningPattern, cap nails or strip
PenetrationsSealed, flashing in place

The sheet is then fastened along the laps and the field. The pattern should follow the manufacturer's instruction, because the sheet is lighter than felt and the wind uplift on an exposed slope acts on a larger area per fastener. A pattern copied from the felt practice is the most common cause of a lap that lifts overnight.

The valleys, the eaves and the penetrations are detailed last as the courses reach them, and each of those is a place where the water resistance depends on the detail rather than on the sheet.

4. Synthetic Underlayment Installation Fastening and Wind Uplift

The fastening pattern is where a synthetic underlayment installation most often differs from the older practice with felt, and it is the detail that decides whether the sheet holds.

Wind uplift acts on the sheet beneath the covering and lifts it at the laps. The load on each fastener rises with the area it holds, so a synthetic sheet that is wider than the felt it replaced carries a greater load at the same fastener spacing.

FactorEffect on the Pattern
Sheet widthWider sheet, more load per fastener
Sheet weightLighter sheet, less resistance to lift
Wind exposureExposed slope, closer spacing
SlopeSteeper area, more uplift at the ridge

The pattern also has to keep the laps closed. A cap nail placed inside the lap holds the two layers together as well as holding the sheet to the deck, and a fastener placed outside the lap holds the upper sheet alone.

The fastening should be confirmed against the manufacturer's instruction for the specific product and the specific wind exposure. A pattern that worked with felt on the same house is not automatically adequate for a lighter, wider synthetic sheet.

5. Case Notes on a North America Roof Underlayment

A roofing contractor in North America wrapped a house with a residential roofing underlayment using the fastening pattern that had been used with felt on the same street. The laps lifted on the gable end after a windy weekend. The pattern was re-set to the manufacturer's figure for the product, and the same sheet held. The material was adequate and the pattern was not.

A second project left a synthetic sheet exposed through a wet autumn while the covering was delayed. The sheet met its stated exposure period and the deck stayed dry. A neighbouring house with felt on the same schedule had the felt crack at the ridge before the covering arrived, and the deck beneath it was wet. The exposure period was the difference in the outcome.

Both cases show the same point. The sheet has to be installed to its own figures rather than to the figures of the product it replaced, and the exposure period is a schedule constraint rather than a property of the material alone.

6. North America Roof Underlayment Details and Penetrations

The details are where a residential roofing underlayment is tested, because the water arrives at the details rather than in the field of the roof.

A valley collects the water from two slopes and delivers it to the gutter. It is treated with a self-adhering shield in addition to the field underlayment, and the shield is laid before the underlayment courses reach it.

The eaves are where ice can back up under the covering in a cold climate. An ice and water shield is used at the eaves for the same reason as in the valley, and it is specified in addition to the field underlayment.

Each penetration, whether a vent, a chimney or a pipe, interrupts the sheet and needs a sealed detail. A penetration that is flashed without a seal at the underlayment leaves a path for water at the one point where the geometry concentrates it.

7. Planning a Synthetic Underlayment Installation

Plan the installation around the exposure period, because the sheet is the sole weather protection on the deck until the covering arrives.

Confirm the fastening pattern against the product and the wind exposure at the site, rather than carrying it over from the previous material.

Order the ice and water shield with the underlayment, so that the valleys and the eaves are detailed with the correct product rather than improvised.

Set the lap widths and check them against the sheet marking during the work. A lap that is narrower than the sheet requires is the failure that appears first in a wind.

8. Residential Roofing Underlayment Supplier Profile

United Perfect Building Materials, part of Jinan United Perfect Building Materials Corporation, produces synthetic roofing underlayment for residential and commercial roofs and supplies buyers in North America. The company quotes the weight, tensile strength, tear resistance and exposure period of each grade, which allows a residential roofing underlayment to be selected against the slope and the schedule of the project.

Jinan United Perfect Building Materials holds retained samples by production batch, so a delivered roll can be checked against the reference used at approval. Buyers planning a synthetic underlayment installation for a project that mixes steep and low-slope areas can order the appropriate grades from one source. United Perfect can also confirm the exposure period in writing where the covering may be delayed.

9. FAQ About Residential Roofing Underlayment

9.1 What underlayment suits a shingle roof?

For most North American shingle roofs a synthetic sheet with a tear resistance suited to the wind exposure serves well, and the specific grade follows from the slope and the exposure period. The underlayment is the secondary layer beneath the shingles, so the sheet has to shed water at the laps and survive the traffic of the installation without tearing at a fastener. Where the roof has valleys, eaves that see ice, or penetrations, a self-adhering shield is added at those details in addition to the field sheet.

9.2 How is the fastening pattern set?

It is set by the manufacturer's instruction for the specific product and by the wind exposure at the site. A synthetic sheet is lighter and often wider than the felt it replaces, so each fastener holds a greater area and the uplift load on it is higher. A pattern copied from a felt installation is the most common cause of a lap that lifts overnight. The fasteners should also be placed inside the lap, so that they hold both layers together rather than the upper sheet alone.

9.3 How long can it be left exposed?

For the stated exposure period of the grade, which should be confirmed with the supplier before the order. A synthetic underlayment is generally rated for a longer exposure than felt, which gives a residential schedule more room between wrapping the deck and installing the covering. That does not make the sheet a finished roof, because UV exposure degrades the polymer over time and exceeding the stated period risks a failure that appears before the covering arrives and is then hidden beneath it.

9.4 Do I need ice and water shield as well?

Yes, in the locations where water can back up under the covering. An ice and water shield is a self-adhering membrane used at the eaves, in valleys and around penetrations, and it is specified in addition to the field underlayment rather than as an alternative. The field sheet covers the general area of the roof, and the shield protects the details where the geometry concentrates water or where ice can push it upward. The two are ordered together as one roof package.

9.5 Is synthetic harder to walk on than felt?

It is generally slicker, particularly when the surface is damp or covered with dust, and a crew used to felt should allow for the difference. The lower friction is a property of the polymer surface, and some products add a textured or printed face to improve footing. On a steep slope, and on a morning with dew, the change in footing matters more than it does on a low-slope roof. Walking on the sheet also loads the fasteners and the laps, so the traffic should be kept to what the installation requires.